Two operative risk indicators as tools for negotiating contracts between curators of Museums and HVAC technical services providers

2020

Abstract The purpose of Heating, Ventilating and Air-Conditioning (HVAC) systems in museums is to properly control important microclimate parameters; such systems, in fact, apart from ensuring the visitors’ wellbeing, are requested to guarantee suitable indoor conditions for the proper conservation of the important cultural goods hosted by museums. Hence, in case of disservice, or interruption due to maintenance interventions, it is important to quantify the economic damage induced to exhibited and/or stored works of art (or even to the building museum itself). Accordingly, it is essential to guarantee the shortest possible period of disservice during which probable damages for the works of…

ArcheologyEnvironmental conditionMaterials Science (miscellaneous)media_common.quotation_subjectControl (management)Psychological interventionConservationStipulationWorks of art preservationHVACRisk indexeMuseumEconomic costHVAC management and maintenance service contractSpectroscopymedia_commonSettore ING-IND/11 - Fisica Tecnica Ambientalebusiness.industryNegotiationWork (electrical)Risk analysis (engineering)Chemistry (miscellaneous)Order (business)DamagesbusinessGeneral Economics Econometrics and FinanceJournal of Cultural Heritage
researchProduct

Risk indexes for studying interconnected earthing systems inside MV networks

2006

The paper presents a risk-evaluation-based approach to the issue of interconnection between the earth electrodes of the MV/LV substations within MV networks. After a short introduction on the interconnection between earthing systems, the paper proposes four risk indexes defined starting from the safety requirements given by CENELEC HD 63 7 S1. The indexes allow one to put in evidence, in a clear way, the benefits of the interconnection in terms of reduction of risk of critical electric shock for persons and of stress on the insulation of the LV devices in the presence of single line to earth faults and double earth faults inside MV/LV substations and single line to earth faults inside HV/MV…

InterconnectionEngineeringElectric shockbusiness.industryrisk indexesmedicineElectrical engineeringelectrical safetyglobal earthing systemsSingle linemedicine.diseaseEarthing systembusinessRisk Analysis V: Simulation and Hazard Mitigation
researchProduct

Suitability of some existing damage indexes for assessing agreements in maintenance and management of museum climatization systems

2020

Heating, Ventilating and Air-Conditioning systems in museums are called to properly control important microclimate parameters, not only for visitors’ wellbeing, but mostly for the preservation of works of art. Accordingly, in case of interruptions to Heating, Ventilating and Air-Conditioning systems, due to maintenance interventions or drawbacks, it is essential to guarantee the acceptable break from service to which possible damages for the works of art are related. In this regard, the aim of this work is to introduce a simple indicator to support curators in regulating the stipulation of contracts with external companies, a more effective management and maintenance of the Heating, V…

Management and maintenance service contractSettore ING-IND/11 - Fisica Tecnica Ambientalelcsh:TRenewable Energy Sustainability and the EnvironmentEnvironmental conditionHeating ventilating and air-conditioningventilating and air-conditioning management and maintenance service contractEnergy Engineering and Power TechnologyheatingEnvironmental Science (miscellaneous)Environmental economicslcsh:Technologylcsh:HD72-88environmental conditionslcsh:Economic growth development planningWorks of art preservationeconomic cost.risk indexesEconomic costRisk indexeMuseumEconomic costBusinessmuseumsWater Science and Technology
researchProduct

Risk indexes evaluation in view of a new showcase designing of “L’Annunciata” by Antonello da Messina

2018

Museums are often hosted by heritage buildings, where the indoor thermal conditions are usually subjected to a free-floating regime, due to the difficulty of equipping them with HVAC systems that, generally, are highly impacting tools from a visual point of view. These technological tools, in fact, could conflict with the established arrangement of the works of art. This would represent a problem, since the indoor physical conditions of these premises must fall within the ranges of values suitable to ensure the safety of the works of art there exhibited. In addition, the increasing time spent by visitors inside museums (now offering various possibilities of leisure, ranging from the book sh…

Settore ING-IND/11 - Fisica Tecnica AmbientaleIndoor museum conditions painting preserving risk indexes showcase.
researchProduct